Redundancy Switch ZTRS6000

 

 

ZTRS6000_klein

 

Zenitel

 

 

 

 

 

 

The redundancy switch ZTRS6000, developed by Zenitel, enables the possibility to connect 2 repeaters / base stations to build an redundant configuration for indoor and special coverage locations.

 

Characteristics

  • Redundant repeater configuration
  • Frequency range 136 – 2200 MHz ( 2 bands)
  • Continuously monitoring of the output power from the repeaters
  • Automatically switching in case of malfunction of one of the repeaters
  • Communication via TCP/IP or RS485
  • Fully web based configuration and monitoring

Options

  • Interfacing with Zenitel's SCADA system ZTSS6000
  • SNMP functionality

 

Description

In HF communicaton systems normally 2 repeaters are used to cover their own part of the antenna system and distribute the HF signals. By implementing the Zenitel redundancy switch it will never occur that malfunction of one repeater will lead to communication problems in that part of the system. The redundancy switch will continuously monitors the HF signals provided and will automatically switch/connect the remaining repeater to that part of the system in case the measured values are below user definable triggerlevels or in case of a complete malfunction of a particular repeater. This results in a redundant system where in case of a emergency one repeater will distribute the HF signals into the complete antenna system. The status of the redundancy switch and both repeater / base stations are presented by the LED's at the front panel of the switch.

Via the web based tool it is possible to remotely configure different parameters and continuously monitor the provided HF power output.

 

Specifications ZTRS6000

 

Electrical  
Frequency band                                      136 – 2200 MHz
Inputs / outputs 2-2
Max input power / channel 10W
Power supply 12 -15VDC
Power consumption  
Impedance  50Ω
External inputs / outputs 2 / 2 (unpolair)
Protocol TCP/IP
   
Mechanical  
Dimensions ZTRS6000 2HE / 350mm
Operating temperature 0 to +55°C
RF connectors N-female
Diagnostic TCP/IP port RJ45 (front)
RS485 communicatie port RJ11
Indicators LED
DC & IN-OUT connector MC1,5/12 ST-3,5
   



Software

  • Simple configurable via web-browser, local or remote
  • Network interface via fixed IP address or DHCP mode
  • Automatic adjustments
  • Interface possible with Zenitel Tunnel Scada System ZTSS6000
  • Extensive status overviews and service tools available
  • User definable minor and major alarms

 

ZTRS6000SW_Front

ZTRS6000_SWZTRS6000_SW

 

 

 

 

 

 

 Main screen ZTRS6000 software                                        Statusscreen